The total mercury (Hg) content of Soil A was determined, by an Accredited Test Lab, to be 238 ppm, and Soil B was determined to be 21,400 ppm.

 

Waste Loading by Weight Soil A
238 ppm Hg
(basic formula)
Soil B
21,400 ppm Hg
(basic formula)
30% 0.012 ppm 0.119 ppm
50% 0.001 ppm 0.193 ppm
70% 0.008 ppm 0.302 ppm

 

Applied Innovations, Inc. Recently Developed Formula for Hazardous Heavy Metal Contaminated Soils, Sludge’s and Various Other Waste Forms.

The total mercury (Hg) content of Soil C was determined, by an Accredited Test Lab, to be 2,000 ppm.

 

Waste Loading by Weight Soil C
2,100 ppm Hg
(new formula)
30% 0.006 ppm
50% <0.0002 ppm
70% 0.0007 ppm
 

 